RCL-CXXW_EHC_Rev.0_05-12-2018 1/26 DSR edge Electric Radiator INSTALLATION & OPERATING INSTRUCTIONS THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE 500w-1000w-1500w-2000w RCL-CXXW_EHC_Rev.0_05-12-2018 2/26 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance. 1. General Information EHC Electric radiators have been designed using the latest technology to create an elegant solution for all hard to heat situations. They can be installed in almost any location, apart from the safety restrictions noted within this manual. This range has been developed to provide a flexible solution for electric heating in Domestic properties, Conservatories, Holiday homes, Offices and in any temporary heating situation. The radiators can be simply plugged into a standard socket or hard wired into a fused spur. Wi-Fi Control DSR Wi-Fi Control is our easy to use App based control system. To take benefit of this feature you simply need to purchase and connect the radiators to our DSR Gateway. The DSR Wi-Fi App gives you total control of all your radiators independently or in groups if required. The system can be controlled from a Computer, Smart phone or Tablet using our Free App. Additionally by adding an optional Power Meter to the system will give you further controllability over the total available power within your home. The Power Meter constantly monitors the whole house electrical demand. If the set demand is reached, the system will temporarily disable your chosen radiators until the demand is reduced, the radiators will then be reactivated automatically. All EHC radiators are manufactured to the highest safety and quality Standards. Each radiator is CE Marked and carries all the necessary European Approvals. Each radiator is fully checked and tested prior to leaving the factory. We hope you enjoy the comfort provided by this superior product and we look forward to being of assistance to you in the future. RCL-CXXW_EHC_Rev.0_05-12-2018 3/26 GENERAL SAFETY INSTRUCTIONS 1. Please read these instructions fully before starting the device for the first time. Do not discard the instructions, guarantee, your invoice and, if possible, the complete packing. 2. The guarantee will be invalidated if the product is not installed or handled in- line with the recommendations of this manual. 3. Before connecting the appliance, make sure the mains voltage is sufficient and in correspondence to the marked labels of the appliance. 4. Check the power is sufficient to supply the appliances. Note; the total draw of the radiators current must not exceed the capacity of the circuit breaker that protects them. 5. This radiator cannot be used in rooms with presence of gases or other flammable products (glues, etc...) 6. WARNING: To prevent overheating, Do Not cover or use the radiator to dry clothes. 7. Make sure the power cable or other objects do not come into contact with the radiator surface while in operation. 8. If the power cable becomes damaged it must be replaced by the manufacturer or a suitably qualified trades person. Failure to comply may compromise your safety and void your warranty. 9. Check the device and the supply cord regularly. Do not turn the device on if it is damaged. 10. PRECAUTION: Some parts of this product can reach high temperatures and could cause burns. Pay special attention when children or vulnerable people are near this radiator. 11. Do not place the device directly under a power socket. 12. Children under the age of 3 should not be allowed to touch or play with the radiator and should be supervised at all times. 13. This device can be switched on/off by children over 8 years of age, as well as by people with reduced physical, sensory or mental capabilities, only when suitably supervised adult is present and only when they have been provided instructions to use of the device. Cleaning must only be carried out by an appropriate adult RCL-CXXW_EHC_Rev.0_05-12-2018 4/26 GENERAL SAFETY INSTRUCTIONS 14. Warning: Do not use this radiator near baths, showers or swimming pools. It should not be possible to access the device's controls from the bath, shower or any other surface that is in contact with water. (Its use in zones 0 or 1 in bathrooms is totally prohibited: seek advice from a qualified electrician). 15. For greater safety, this appliance is provided with a device that interrupts its operation in the case of overheating. 16. This radiator has been designed exclusively to be fixed to the wall. For further information on the fixing systems, consult the section "INSTALLATION AND WALL MOUNTING" of this manual. 17. Do not use accessories that have not been recommended by the manufacturer, as they could entail a potential risk to the user, and damage the device. Use only original accessories. 18. Keep all the packaging elements (plastic bags, cardboard and polyethylene) out of the reach of children, as they can cause potentially dangerous situations. 19. Use this device only for domestic / light commercial use and the tasks for which it has been designed. This device has not been designed for industrial use. It must not be used outdoors, in greenhouses or for animal husbandry. Keep it away from heat, direct sunlight, humidity and cutting tools. Do not under any circumstances immerse in water or use this device with wet hands. In the case of humidity or water in the device, immediately disconnect the power supply and do not touch the wet parts. 20. Do not attempt to service the device yourself. Contact a qualified technician. 21. To disconnect the radiator from a mains socket, pull the plug, never the supply cord. 22. Respect the "SPECIFIC SAFETY INSTRUCTIONS FOR THIS APPLIANCE" RCL-CXXW_EHC_Rev.0_05-12-2018 5/26 SPECIFIC SAFETY INSTRUCTIONS FOR THIS DEVICE • The appliance must remain in a vertical position. • Make sure the appliance is secured at all times. Please adhere to the installation distances indicated in this guide. • Do not hang any objects in front, behind or on top of the device. • Always ensure that the inlet and outlet air flow are not obstructed. • Always install the device so that it cannot enter into contact with any combustible material, such as curtains or towels. • To clean the device, consult the instructions in the "MAINTENANCE" section. If water enters the radiator it could seriously damage the device. • Do not insert any object through the grille or inside the device. • This radiator is designed to be connected by plug to the electric installation and fixed to the wall installation. Follow the instructions in "INSTALLATION". Your Guarantee may be invalidated if the installation instructions have not been followed INSTALLATION • Radiators can be heavy. Take adequate precautions when lifting and maneuvering the radiator. Always assess the load, and seek assistance with heavy or awkward loads that are beyond your capabilities. • In order to maintain stability and to ensure its future safety in use, it is essential that the radiator is FIXED SOUNDLY TO A WALL and that the brackets are mounted on a FIRM, LEVEL SURFACE. • Care should be taken to avoid irregular surfaces. • It is important that these instructions are strictly followed. • Keep the following minimum safety distances to avoid fire risk due to high surface temperatures of the appliance during heating cycles. RCL-CXXW_EHC_Rev.0_05-12-2018 6/26 • CAUTION – This radiator must not be located below or in front of a fixed socket outlet. • DO NOT POSITION under windows where curtains may contact the radiator. • DO NOT PLACE THE APPLIANCE in the vicinity of a swimming pool. • During the first use and for a few minutes, this device may occur smells and noise due to the dilatation of some internal parts. This is normal, so you must provide adequate ventilation. The smells are momentary and will quickly dissipate. • For greater efficiency, make sure to calculate the correct size of the radiator according to the surface of the room. We recommend contacting your dealer or engineer to perform this calculation. • The radiator must be placed at a minimum distance of 15cm from any combustible material, curtains, furniture, chairs, etc. (Fig.1). • Allow for a minimum distance of 1m, from the front of the unit to any obstacles (furniture, walls, curtains, for example) that could hinder its operation or performance of the product. • Keep a minimum distance of 15cm between the appliance and the side walls and any other obstacles (walls, for example) that may affect its function. Also keep a minimum distance of 35cm on top the appliance free of obstacles and a minimum distance of 15cm from the floor. RCL-CXXW_EHC_Rev.0_05-12-2018 7/26 Fig1 Minimum Clearances Note: Only IPX4 radiators are suitable for installation in bathrooms which allows for the radiator to be installed within Zone 2 as per regulation 701.32.4 Regulation 701.411.3.3 of BS7671 means that all circuits within a location containing a bath or shower will require RCD protection not exceeding 30 mA and have the characteristics specified in regulation 415.1. Local isolation should be provided for the radiator, however, the isolation device must be installed out with all zones and in compliance with regulation 701.512.3 and Section 53 of BS7671 Note: Radiators must be only installed in or out with zone 2 of a bathroom Possible Shelf RCL-CXXW_EHC_Rev.0_05-12-2018 8/26 WALL-MOUNTING The appliance is equipped with 2 radiator's suspension supports. Fig.3 1. Place the radiator on the floor and against the wall that it is to be fitted onto. 2. Position the two brackets (supplied) by placing them on top of the radiator. Refer to Figure 3 3. Mark the wall to indicate the corresponding drilling points. 4. Using the self-adhesive strip, stick the plastic stoppers onto the lower part of the radiator by removing the paper cover and press into position hold for at least 3 seconds. Refer to Figure 4 Fig.4 Note: Adhere the stopper onto the radiator and not the end panel. Refer to Figure 4 5. Drill and Fix the brackets to the wall using the screws and rawl plugs provided. Finally, mount the radiator onto the brackets and screw the safety lock into place until you feel it becoming tight. Refer to Figure 5 Fig.5 RCL-CXXW_EHC_Rev.0_05-12-2018 9/26 ELECTRIC CONNECTION The appliance has been designed to be connected to 230V (nominal) alternating current (AC); 50Hz power supply. This appliance is equipped with a 1.5 m supply cord fitted with standard UK sealed 3 pin plug that can be directly connected to a suitable electrical sockets within the home. Care must be taken when connecting radiators in this way not to overload the ring main circuit within the property. If you are unsure contact a qualified electrician for advice. Alternatively the supply cord can be cut to length by a Qualified Electrician and connected to a suitable 13A DP Switched Fuse Spur installed adjacent to the radiator. This connection unit should comply with BS 1364-4 and have a minimum contact separation of at least 3mm. It is recommended when connecting to a screwed terminal that the flex ends are crimped to prevent the copper strands from splaying within the terminal. All electrical installation work, in particular protective measures, must be carried out in compliance with BS7671 regulations, statutory provisions and ‘best industry practice’ of the respective utilities provider. The electrical installation may only be carried out in compliance with the installation instructions by a suitably qualified electrician. Electrical Connections The wires within the supply cord are coloured in accordance with the following code: BLUE: NEUTRAL BROWN: LIVE GREEN/YELLOW EARTH WARNING THIS APPLIANCE MUST BE EARTHED Next >